''(2) When there are no instructions by the manufacturer respecting the shaking of the spray container, a test must be conducted as'' follows, using each of three spray containers of the same product and of the same size:''
 
''(2) When there are no instructions by the manufacturer respecting the shaking of the spray container, a test must be conducted as'' follows, using each of three spray containers of the same product and of the same size:''
 +
  
 
''*(a) without shaking the container, discharge it three times as described in paragraph 4(9)(b); and''
 
''*(a) without shaking the container, discharge it three times as described in paragraph 4(9)(b); and''
Line 67: Line 68:
  
  
==CCCR Technical Amendments - Schedule 1, Sections 1 and 2==
+
==CCCR Technical Amendments - Schedule 1, Section 3==
There are a number of references to section 34 in the [http://www.hc-sc.gc.ca/cps-spc/legislation/acts-lois/techni_e.html Proposed Technical Amendments to the Consumer Chemicals and Containers Regulations, 2001].  They are as follows:
+
There are a number of references to schedule 1, section 3 in the [http://www.hc-sc.gc.ca/cps-spc/legislation/acts-lois/techni_e.html Proposed Technical Amendments to the Consumer Chemicals and Containers Regulations, 2001].  They are as follows:
  
  
Line 74: Line 75:
  
  
* There is an inconsistency between the text and Figures 1 and 2 of the testing apparatus. The height of the internal open space should be 45 cm, as indicated in the figures. (Section 2)
+
* The number of sprays required for pump-spray containers is excessive and time-consuming. For example, it is possible that a test container would need 1200 sprays (not including priming and trial discharges to adjust the flame). As a result, it is conceivable that the product could be used-up before the test is completed.
  
  
* The number of sprays required for pump-spray containers is excessive and time-consuming. For example, it is possible that a test container would need 1200 sprays (not including priming and trial discharges to adjust the flame). As a result, it is conceivable that the product could be used-up before the test is completed.
+
Without compromising the integrity of the test results, the number of sprays per discharge from a pump-spray container can be reduced from 10 to 3, and the number of discharges can be reduced to that required for pressurized containers. This would reduce the total possible number of sprays from 1200 to 108. (Sections 3 and 4)
 +
 
 +
 
 +
* The need to shake the container prior to testing must be clarified. When shaking is called-for, the container should also be shaken between discharges. Hence, it is not necessary to wait 60 seconds between discharges, prior to re-shaking the container. (Sections 3 and 4)
  
  
Line 83: Line 87:
  
  
Clause 2(a)(iv)(A) of Schedule 1 to the Regulations is replaced by the following:
+
Section 3 of Schedule 1 to the Regulations is replaced by the following:
 +
 
 +
 
 +
3. (1) When there are instructions by the manufacturer respecting the shaking of the spray container, a test must be conducted as follows, using each of three spray containers of the same product and of the same size:
 +
 
 +
 
 +
* (a) if shaking is applicable, shake and discharge the container as described in paragraph 4(9)(a) three times; or
 +
 
 +
 
 +
* (b) if shaking is not applicable, discharge the container three times as described in paragraph 4(9)(b).
 +
 
 +
 
 +
(2) When there are no instructions by the manufacturer respecting the shaking of the spray container, a test must be conducted as'' follows, using each of three spray containers of the same product and of the same size:
 +
 
 +
 
 +
*(a) without shaking the container, discharge it three times as described in paragraph 4(9)(b); and
 +
 
 +
 
 +
(b) shake and discharge the container as described in paragraph 4(9)(a) a further three times.
 +
 
 +
 
 +
The portion of subparagraph 4(3)(b)(ii) of Schedule 1 to the English version of the Regulations before clause (A) is replaced by the following:
  
  
(A) has an internal open space of 35 cm wide by 45 cm high,''
+
(ii) in the case of a pump-spray container, activating the trigger or pump using each of 18 N, 36 N and 54 N of force for each possible nozzle position until
  
  
Line 107: Line 132:
  
 
==Canadian Goverment Links==
 
==Canadian Goverment Links==
*[http://www.hc-sc.gc.ca/cps-spc/pubs/indust/cccr-2001-rpccc/ref_man/sec-33-article_e.html CCCR Reference Manual, Sections 33 and 34]
 
 
*[http://www.hc-sc.gc.ca/cps-spc/legislation/acts-lois/techni_e.html Proposed Technical Amendments to the Consumer Chemicals and Containers Regulations, 2001]
 
*[http://www.hc-sc.gc.ca/cps-spc/legislation/acts-lois/techni_e.html Proposed Technical Amendments to the Consumer Chemicals and Containers Regulations, 2001]
  

Revision as of 16:43, 6 January 2008

Personal tools
Namespaces

Variants
Actions
Navigation
Toolbox